BREEAM V7 update. The Security Needs Assessment credit has been renumbered to Hea 08; it was Hea 06 in previous manuals.
A perceived sense of security and safety is undeniably essential to enabling sustainable and successful schemes. The fear of crime or perceived threat to physical safety can reduce the overall productivity and wellbeing of the scheme’s occupants. All schemes, whether residential or commercial, should have the appropriate planning, design and specifications to enable a physically secure environment.
ADW Developments has substantial expertise in helping clients design their schemes in a manner that mitigates identifiable security risks and feature proactive security measures thus improving the scheme’s security and safety outcomes. Our associate experts are certified to carry out the BREEAM-approved security risk management standard, SABRE. This standard offers an exemplary security label and quantifiable reduction in security risks.
Our approach to security is to conduct a Security Needs Assessment study by an accredited, suitably qualified security specialist. This assessment features a review of local crime statistics, as well as a visual audit of the site surroundings, and finally a review of the current design proposals. Recommendations are then given to the design team to help them mitigate any safety and security issues which have been identified.
Who can carry it out
BREEAM defines a Suitably Qualified Security Specialist precisely, and it is not a role the architect or the M&E engineer can absorb. The specialist either has three years of relevant security experience in the last five, a security qualification and full membership of a professional body with a code of conduct, or is registered with a scheme BREEAM recognises, such as SABRE Registered Professionals with SQSS status, Chartered Security Professionals or the Register of Security Engineers and Specialists.
They should also be independent of the design team. A Designing Out Crime Officer from the local police can contribute, and BREEAM encourages it, but cannot stand in for the specialist. An appraisal written by the people who drew the scheme describes the design rather than checking it.
Why it has to happen by Stage 2
BREEAM expects the assessment during or before concept design, and that is where the cost of the credit is decided. Most good security design is layout: sightlines, natural surveillance, where the entrances go, and where public space ends and private space begins. Change those at Stage 2 and the cost is a redrawn plan. At Stage 4 the layout is fixed, and the only way left to meet the recommendations is equipment: cameras, access control, lighting and barriers.